Click Here to Discover Your Survival Rating Score 🔥

TALK TO A REAL PERSON

M-F 9am-5pm CST

  • Best-In-Class Survival Gear

    Built by preppers, for preppers.

  • Free Shipping in Canada

    When you spend $100

  • Free Shipping to USA

    When you spend $200

  • 30-Day Money Back Guarantee

    Hassle-free returns on most orders

Mira Safety

MIRA Safety Tactical Air-Purifying Respirator (TAPR)

$285.00 CAD
Shipping calculated at checkout.

30-Day Money Back Guarantee
Hassle-free returns on Most Orders

Delivery and Shipping

United States: Free standard shipping on orders over $200.
Canada
: Free standard shipping on orders over $100 to BC, AB, SK, MB, and ON

Delivery Times

Canada: 3-7 business days after processing.
**Please note**
Canada Post is currently on Strike which may delay shipping times
- We have other shipping providers available.

United States: 5-10 business days after processing.

For More information, please see our Shipping Policy

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

The Tactical Air-Purifying Respirator (TAPR) is the first EN-140 certified half-face respirator mask specifically designed for special operations, security actions, and rescue teams. Originally developed to suit the needs of the Czech Special Forces, the TAPR is designed to provide flexible, versatile protection for even the most challenging tactical situations.

KEY FEATURES OF THE TAPR RESPIRATOR MASK:

  • Innovative, shooter-friendly design proven by active duty military
  • Uses widely available NATO-standard, 40-mm filter cartridges
  • Custom mesh head harness for standalone use
  • Optional FidLock buckle system for rapid deployment with helmets that use the popular ARC rail or M-LOK system
  • Compatible with popular riot control helmet systems, including MSA Gallet and Schuberth riot control helmets
  • Compatible with a wide variety of protective goggles, shields, and face masks
  • Comes with a hardened travel case
  • Ultralight construction (just over 4 oz. without filter)
  • Built from high-quality sanitary silicone rubber
  • Anatomical design and unique harness system provide true one-size-fits-all protection
  • Compatible with our proprietary MIRA Gas Mask Microphone (sold separately)
  • Ideal for use with one of three compact gas mask filters (P-CAN Compact, Particlemax P3 Compact, and NBC-17 SOF)
  • Dual exhalation valves for easy breathing during long hours of use
  • Can be cleaned with common disinfectants for regular/repeated use
  • The mask body has a 20-year shelf-life while the head harness and valves have a shelf-life of 10 years and 5 years respectively
  • Carries MIRA Safety’s 1-year manufacturer warranty

Today’s special forces and elite law enforcement professionals face an unprecedented range of threats in the field.

And compromising tactical effectiveness for protection simply isn’t an option.

The TAPR is a modular half-face respirator platform that can be configured to integrate with most popular helmet systems and communications gear. It’s engineered for rapid deployment and reliable protection while preserving combat readiness and freedom of movement.

Designed to integrate seamlessly into your plate carrier, battle belt, or rig with the included pouch, the TAPR is often the best practical protection you can carry against a range of lethal and nonlethal threats.

MAXIMUM FLEXIBILITY FOR LIMITLESS APPLICATIONS

Tactical Operations

The TAPR was specifically designed to help top operators tackle dynamic, real-life threats. With years of deployment and active combat use, the TAPR is a top choice among military professionals.

Riot Control & SWAT Use
Police & Emergency Patrol
Readiness Planning
Particulate Protection and More
Shooting Range Protection

WHAT’S IN THE BOX?

The standard TAPR Kit comes with the following:

Center Port TAPR Body

Made from silicone rubber for comfort, it has two exhalation ports and a central 40-mm NATO threaded filter connector.

Mesh Head Harness
ParticleMax P3 Compact Filter
P-CAN Compact Filter
Carry Case
Nylon Pouch
Low-Profile Exhalation Cap

OPTIONAL EQUIPMENT

Along with the accessories that come with the TAPR Standard Kit, several additional accessories are available to expand functionality:

MIRA Safety Gas Mask Microphone

Make your mask comms-ready with an integrated microphone that’s compatible with Peltor and Ops-Core headsets.

ARC Rail / M-LOK Fidlock Connectors
M-LOK Adapters
MSA Gallet “German” Adapter Kit
Custom Right- or Left-Handed Shooter Configuration Body
NBC-17 SOF Filter

IMPORTANT NOTE: Half-face masks do not provide sufficient protection from CBRN threats, and the TAPR was NOT designed for prolonged exposure to unknown environments, blister agents, or toxic industrial chemicals. Selection of a suitable filter depends on the type and concentration of the anticipated toxic agent. The TAPR equipped with a TIC or CWA filter is only safe for use in an environment containing at least 19.5% oxygen. The principles of filter selection and application are described in the filter user guides.

TAPR RESPIRATOR MASK TECHNICAL DATA:


Weight:                          120 g
Size:                               Universal Fit
Filter Connection:         EN 148-1, NATO STANAG 4155, 40×1/7“
Facepiece Material:      Silicone rubber
Color:                             Black
_______
Inhalation Resistance: 
30 l/min flow rate max. 15 Pa
160 l/min flow rate max. 135 Pa

TAPR STORAGE

The TAPR military half-face respirator must be stored in a dark, cool, and dust-free location that’s free from sudden temperature changes. The storage room should be ventilated regularly. Temperatures may vary between 5°C and 25°C with relative humidity up to 65%. Full-face gas masks must not be exposed to radiant heat or sunshine. Fuels, solvents, lubricants, and other inflammable substances, including chemicals, must not be stored with masks. Moreover, there must not be any electrical machines or appliances that produce sparks or discharges during operation (ozone creation).

Avoid deformation of the rubber parts of the facepiece during storage.